Installation Instructions for Self-levelling Manhole Covers

ECON SN 600/190

Height: 190 mm

more information

We recommend using the installation frame. The optimum installation height from the top edge of the finished road to the top edge of the support ring (cone) is 160 mm and can be varied from 140 mm - 180 mm.

Recommandation

When installing the manhole covers in road surfaces with a greater longitudinal or transverse gradient of the road, support rings with a larger internal diameter than 625 mm are useful.

Accessories

PDF

ECON SN 600/275

Height: 275 mm

more information

We recommend using the installation frame. The optimum installation height from the top edge of the finished road to the top edge of the support ring (cone) is 250 mm and can be varied from 140 mm - 265 mm. Check the clear opening - at least 625 mm.

Recommandation

When installing the SN manhole covers in road surfaces with a greater longitudinal or transverse gradient of the road, support rings with a larger internal diameter than 625 mm are useful.

Accessories

PDF

ECON SN 800

Height: 230 mm

more information

We recommend using the installation frame. The optimum installation height from the top edge of the finished road to the top edge of the support ring (cone) is 280 mm and can be varied from 240 mm - 320 mm. Check the clear width - at least 800 mm.

Recommandation

Installation with a cast iron adapter ring is recommended.

Accessories

PDF

Manhole Cover SN

Height: 210 mm

more information

We recommend using the installation. The optimum installation height from the top edge of the finished road to the top edge of the support ring (cone) is 175 mm and can be varied from 150 mm - 200 mm. Please note that a concrete/cast cover must not be subjected to vibrations.

Recommandation

When installing the manhole covers in road surfaces with a greater longitudinal or transverse gradient of the road, support rings with a larger internal diameter than 625 mm are useful.

Accessories

PDF

Manhole Cover SN

Height: 250 mm

more information

We recommend using the installation frame. The optimum installation height from the top edge of the finished road to the top edge of the support ring (cone) is 200 mm and can be varied from 170 mm - 240 mm. Please note that a cover with concrete filling must not be stressed with vibrators.

Recommandation

When installing the manhole covers in road surfaces with a greater longitudinal or transverse gradient of the road, support rings with a larger internal diameter than 625 mm are useful.

Accessories

PDF

TITONpur SN

Height: 210 mm

more information

We recommend using the installation frame. The optimum installation height from the top edge of the finished road to the top edge of the support ring (cone) is 175 mm and can be varied from 150 mm - 200 mm. Protect from direct contact with hot asphalt!

Recommandation

When installing the manhole covers in road surfaces with a greater longitudinal or transverse gradient of the road, support rings with a larger internal diameter than 625 mm are useful.

Accessories

PDF

General Instructions for the Installation of Manhole Covers

The installation instructions given are only to be understood as recommendations. The civil engineering companies commissioned with the installation can of course reserve the right to make possible improvements during installation. The civil engineering company is responsible for the correct installation of the manhole cover. This means that all technical regulations in the respective version must be observed and complied with.

Today, a variety of common installation methods are known. The choice of the most suitable installation method for your case is the responsibility of the commissioned specialist planner, who has the necessary knowledge to assess the situation.

When choosing the mortar quality to be used, there is also a wide range of offers on the market, the suitability of which for your case can best be carried out by the commissioned specialist planner.

All parts to be installed must be checked for possible damage before processing. Damaged parts must not be installed under any circumstances for liability reasons, but a complaint must be made immediately.

Installation of the Manhole Cover TITONpur SN

Installation Instruction for Self-levelling Manhole Covers